Industrial PCs and Panel Displays for Class I Division 2 Hazardous Locations

Rated Class I Division 2 for Groups A to D, the workstation, the monitor series and the standalone hazardous location industrial computer mount in panels.

Talk to a Dynics Engineer

An engineer sizes the right unit with you.

Compare Ratings by Unit

Designed, engineered and assembled in Ann Arbor, Michigan. Founded in 1997.

FX-SW-PIX-HAZ Industrial Workstation, angled view of the panel-mount display and its rear computer module

FX-SW-PIX-HAZ Industrial Workstation

Class I, Division 2 · Groups A, B, C and D · T4A

Class, Division and Group Ratings by Product

FX-SW-PIX-HAZ Industrial Workstation FX-SW-HAZ Monitor Series Standalone HazLoc Computer
Class I, Division 2 (gases and vapors) Groups A, B, C and D
Class II, Division 2 (dusts) Groups F and G Not rated
Class III (fibers and flyings) Rated Not rated
Temperature code T4A

Map Your Classified Area

Division 1

Class I and II Division 1, outside these ratings

Division 2

All three units are rated Class I, Division 2.

Unclassified

Panels outside the classified area

See the wider Dynics industrial PC range
Class I
Material in the air
Flammable gas or vapor is or may be in the air, enough to form an explosive or ignitable mixture.
Division 2
How likely
Division 2 includes areas where the gas is normally confined, escaping only through accident or abnormal operation.
Groups A to D
Substance
NFPA 70 Group A is acetylene. B, C and D cover gases like hydrogen, ethylene and propane. The rated Group must match the gas.
T4A
Temperature code
The HAZ data sheets list T4A, which Dynics publishes as 120 °C (248 °F).
Groups and typical substances by class
Class I, flammable gases or vapors
Group A acetylene, Group B hydrogen and similar gases, Group C ethylene and similar gases, Group D propane and similar gases
Class II, combustible dust
Group F carbonaceous dusts, Group G non-conductive dusts such as flour, grain, wood and plastic
Class III, easily ignitable fibers or flyings
Fibers, as found in parts of textile mills and woodworking plants
How Class, Division and Group fit together

OSHA training material uses a storage area with LP gas in closed tanks as its example. Flammable gas puts it in Class I. The area is Division 2 because the gas would reach the air only through an accidental rupture or leak, and LP gas is Group D material. Class I, Division 2, Group D falls within the ratings of all three units.

If ignitable concentrations of the same gas could exist in normal operation, the area would be Division 1, outside these ratings. The closest Division 2 case in 29 CFR 1910.399 follows the same logic. Flammable liquids or gases are handled but normally stay in closed containers or systems, escaping only through accidental rupture, breakdown or abnormal operation of equipment.

The Group letter comes from the National Electrical Code (NFPA 70), which sorts gases, vapors and dusts by how they ignite or burn. Temperature is a separate check. A unit's temperature marking may not exceed the ignition temperature of the specific gas or vapor present on site, a limit set in 29 CFR 1910.307.

One Unit or Two

FX-SW-PIX-HAZ Industrial Workstation rear view, with the computer module mounted on the back of the display
Display and computer in one unit

FX-SW-PIX-HAZ Industrial Workstation

Form factor
Panel-mount workstation with 0, 1 or 2 slots for half-size cards
Front rating
NEMA 4 black powder coat or NEMA 4X stainless steel
Operating temperature
0 to 55 °C (32 to 131 °F)
See workstation details
FX-SW-HAZ Monitor Series rear view, a display-only back with input ports
Add the standalone computer for a slim panel PC

FX-SW-HAZ Monitor Series

Form factor
Panel-mount hazardous area monitors
FX sizes
12.1", 15", 17" or 19"
SW widescreen sizes
12.1", 15.6", 18.5", 21.5" or 24"
Front rating
NEMA 4 powder coated black or NEMA 4X stainless steel
Operating temperature
0 to 55 °C (32 to 131 °F)
See monitor sizes and details
Standalone HazLoc Computer, a black metal box PC with front ports and side mounting flanges
Gases and vapors only

Standalone HazLoc Computer

Form factor
Hazardous area computer in five slot configurations, with panel mount brackets
Options
Motherboard, memory, power and storage
Operating temperature
0 to 55 °C (32 to 131 °F)
See standalone computer details

Designed, Engineered and Assembled in Ann Arbor

Dynics staff assembling industrial displays at workbenches on the Ann Arbor production floor

1997

Founded. Headquarters, 620 Technology Drive, Ann Arbor.

  • Metal fabrication for every unit is done in-house
  • More than 75% of staff work on product development, design, assembly and service

Send the panel size, operating environment and interface needs for your application.

Install Conditions for All Three Units

  1. Enclosure

    Each unit must sit in an enclosure suited to the environment, reachable only with a tool. None runs as a standalone or desktop device.

  2. Wiring

    Wiring must meet the application's standards. The sheets also say to consult local codes.

All three units are open construction, and their 55 °C limit applies to the air inside the enclosure, not the room around it.

An engineer helps pick the unit for your environment.

Questions About Class I Division 2 Computers and Hazardous Area Monitors

What is the difference between Division 1 and Division 2?

Division 1 means the hazard may exist in normal operation. Ignitable gas or vapor may be present while the process runs, or often during repair, maintenance or leaks, under 29 CFR 1910.399. A breakdown that might release gas and also make electric equipment fail qualifies as well. Division 2 is the abnormal case, where gas normally stays in closed systems or ventilation normally holds it below ignitable levels but could fail. Areas next to Division 1 count too when vapors might occasionally reach them without adequate positive-pressure ventilation and safeguards.

What is a Class I Division 2 computer?

A Class I Division 2 computer is approved for Division 2 gas and vapor areas. The approval must also match the specific gas present. Each unit must be marked with class, group and operating temperature for a 40 °C ambient, with exceptions for some equipment, under 29 CFR 1910.307. All three Dynics units are UL Listed for Class I Division 2, Groups A, B, C and D. Their temperature code is T4A, a maximum surface temperature of 120 °C (248 °F).

Do hazardous location PCs need an enclosure?

Yes, for all three units. Each data sheet requires an enclosure suitable for the environment, so the unit is reachable only with a tool. No unit can be installed as a standalone or desktop device. The FX-PIX-HAZ workstation is marked for mounting on a flat surface of an enclosure rated Type 3R, 3S, 4, 4X, 5 or 12. The units are open construction, and their 55 °C limit is the air inside the enclosure, not the room around it.

Where are hazardous location computers used?

Petroleum refineries, gasoline storage and dispensing areas, dry cleaning plants and spray finishing areas are typical Class I locations in OSHA training material. So are aircraft hangars, fuel servicing areas, utility gas plants and LP or natural gas storage sites. In these hazardous locations, the area classification decides the Division, and only Division 2 areas fall within the Dynics ratings. For utility and power sites, see industrial PCs for energy.

Is an explosion-proof or intrinsically safe computer the same as a Class I Division 2 computer?

No. Class I Division 2 rates the location. Explosion-proof is a protection technique, a case that withstands an internal explosion of a specified gas without igniting outside gas. Equipment so enclosed may go in Class I, Division 1 and 2 locations it is approved for, under 29 CFR 1910.307. Intrinsically safe equipment and its associated wiring go anywhere they are approved for. Every Dynics unit uses nonincendive protection, a method that applies to Division 2 only. Division 2 units are the only ones Dynics offers.

Does mounting a Division 2 unit in a purged enclosure make it Division 1?

No. Purging holds air or inert gas inside the enclosure at a positive pressure against the surrounding atmosphere. That pressure is monitored, maintained and controlled, so an ignitable atmosphere cannot reach energized parts. The method can serve Division 1 or 2. A Dynics unit can be panel mounted in a purged enclosure. The unit stays Division 2. It can be used in a purged system, but it cannot complete the enclosure. You are responsible for the design and acceptability of a purged approach for your application.

FX-SW-HAZ Monitor Series angled front view of the panel-mount display

Size a Unit for Your Classified Area

Tell us the Class, Division and Group and the panel cutout for your hazloc display.

Match a HazLoc Unit to Your Panel

A Dynics engineer sizes a rated unit from those details.

Find a Distributor