PCs and OT security for automotive automation
Equip your automotive manufacturing automation with plant-floor computers beside PLCs and a network that carries only allowed traffic.
Panel PCs and computer nodes designed, fabricated and assembled in Ann Arbor.
Production often can't stop, yet flat networks widen attack radius
- Corporate IT networkAttackers may enter through your business network.
- Remote accessOffsite sessions that reach into your OT network.
- Compromised credentialsA valid login in an attacker's hands.
- LaptopsPortable machines that may give attackers entry.
NIST SP 800-82 Rev. 3 notes OT systems often cannot stop and start without affecting production.
Meet automaker security requirements on the network you already run
Your automaker customers' security requirements reach you through procurement and bid packages. DYNICS helps you meet them without redesigning your network.
IEC 62443-aligned architecture
Group assets into zones and control the conduits between them
ICS360.Defender supports environments that have to meet IEC 62443, with deep packet inspection and secure remote access.
OT cybersecurity and asset discovery
Zero trust
Nothing on the line communicates unless it is explicitly allowed
The OT SDN Controller blocks by default, so devices communicate only over paths you permit.
OT networking and segmentation
Network segmentation
Production areas separated so traffic stays where it belongs
The OT SDN Controller enforces OT network segmentation at SDN-capable switches, with no complex VLANs or PLC changes.
OT networking and segmentation
Secure data sharing with automakers
Production data reaches automaker systems over controlled, protected paths
ICS360.Fusion collects data from OT devices and connects it to enterprise resources and cloud service providers.
Data, visualization and edge connectivity
How DYNICS fits around your running line
The work is planned around your running line and your maintenance windows.
Learn the network
Learn mode watches the traffic your line already sends and builds rules from it.
Design zones and policies
Zones and policies are drawn around the way your plant actually runs.
Validate before enforcing
Alert-only mode shows which connections would be affected, without blocking production traffic.
Introduce zones gradually
Policies go in during planned maintenance, one production area at a time.
Update from the console
Per DYNICS, ICS360.DCC sends configuration changes to ICS360.Defender units without production loss or downtime.
What stays in place
- Your existing firewall boundaries
- Older PLCs and their current configurations
- Your current network design
Control supplier access and segment your OT network
Only traffic you explicitly allow crosses your plant network. In DYNICS OT cybersecurity, the OT SDN Controller denies everything else by default.
Outside the plant
- Supplier teams and vendors
At the network edge

ICS360.Defender industrial security platform
- Nearly real-time visibility and deep packet inspection firewalling
- Secure remote access to OT systems
Inside the plant network

OT SDN Controller, software-defined networking
- No device talks without your explicit permission
- Micro-segmentation without complex VLANs
On the line
- PLCs, HMIs and PCs
Deny and allow policies
For example, your team can switch from default deny to an operational allow policy in the interface during a supplier visit.

Industrial PCs that work beside your PLCs
Your PLC keeps logic. An industrial PC handles computing beside it, as compact DYNICS units do in automotive plant-floor panels.
- Operator HMI
- FlexPanel Pro, a fanless, maintenance-free HMI unit.
- Edge data
- Computer nodes for edge computing and data acquisition.
- Visualization station
- A cabinet-mounted node drives a monitor placed elsewhere.
- Enclosed workstation
- Each one built to order in Ann Arbor.
Turn PLC data into live line dashboards with ICS360.Fusion
Put machine states, equipment activity and process conditions on screens in the production area.
Connect
Link OT devices, enterprise resources and cloud service providers.
Read and write
Build flows that read and write PLCs and databases.
Show
In the case below, dashboards ran on a 55-inch overhead monitor.
Send your PLC data to live dashboards and databases.
See ICS360.FusionHow one automotive plant isolated its supplier networks
Independent third-party supplier networks in one shared production environment
- Challenge
- Each supplier network needed isolation, and OT data had to reach the enterprise securely.
- Approach
- ICS360.Defender and industrial switching isolated each network, and permissions changed by authenticated supplier.
- Result
- Supplier networks were isolated, unauthorized lateral movement prevented, and OT data reached the enterprise.
The full write-up shows how ICS360.Fusion collected supplier data while isolated from supplier logins.
Read the Case StudyHardware, software and OT security products
One platform for every layer of your plant, from the shop floor to the top floor.
Secure IT/OT DMZ
Firewall protection, secure remote access and data exchange between IT and OT.
OT cybersecurity and asset discovery
Inspect, protect, manage access
OT networking and segmentation
Connect, segment, control
Data, visualization and edge connectivity
Collect, integrate, visualize
Industrial compute and operator interface
Run, operate, control
FlexPanel ProFanless HMI in five screen sizes
Small FormatAnn Arbor-built panel PCs and nodes
Large FormatHigh-brightness touchscreen displays for control rooms
ThinManager Enabled DevicesPCs and workstations for centralized visualization
3D Vision & Artificial IntelligenceAI inferencing and 3D vision hardware
Services and support
Hardware deployment, system integration and configuration, plus service, support and maintenance.
Where your plant-floor hardware is made
Hardware designed and manufactured in the US, with custom enclosures fabricated in-house. Buy direct or from a distributor.
Find a DistributorAutomotive automation questions about PCs and security
Where do industrial PCs fit in automotive industrial automation?
Beside the PLC, which keeps control. They are built for production settings where dust, heat, vibration or nonstop use can shorten office hardware life.
Which cybersecurity for automotive manufacturing fits a purely OT network?
ICS360.Defender, an industrial security platform, supports a purely OT environment or one where OT and IT converge.
Do older PLCs need replacing before you segment the network?
No. The OT SDN Controller can lock down even the oldest PLCs without upgrading them. It requires SDN-capable switches.
What DYNICS software covers alarms, trends and andon visualization?
ProViewDS, DYNICS industrial digital signage software, controls alarms, trends and graphical displays. Its typical applications include advanced andon visualization.
Can we meet automaker IEC 62443 requirements without redesigning our plant network?
Yes. Segmentation is added inside your OT network while existing firewall boundaries stay. Where a controller falls short, a documented compensating control may meet the requirement. ICS360.Defender supports environments that have to meet IEC 62443.
Tell us what the line needs
Send panel size, operating environment and interface needs. An engineer sizes the unit with you.
Request a QuoteSecure Your OT Network
DYNICS is based at 620 Technology Drive, Ann Arbor, Michigan.





